Site Information for Leeds Centre(UKA00222)

Leeds Centre Information

The monitoring station is located within a self-contained, air-conditioned housing located approximately 30 metres from a busy 4-lane inner-city road, the A660 which is subject to periodic congestion during peak periods. The location is approximately 150 metres from an urban motorway, the A58(M). The surrounding area is generally open and comprises a busy urban setting road network.

UK-AIR ID: UKA00222

EU Site ID: GB0584A

Altitude (metres): 78

Environment Type: Urban Background

PM2.5 Targets This site is used in the assessment of both the Annual Mean Concentration Target (AMCT) and Population Exposure Reduction Target (PERT) under the Environmental Target (Fine Particulate Matter) (England) Regulations 2023, subject to meeting the inclusion criteria on an annual basis. To find out more about how measurements are used to calculate progress towards the targets and which sites have met the inclusion criteria in different years, please see the PM2.5 target calculation page.

Site Location

Environment Type: Urban Background

Site Address: Leeds

Government Region: Yorkshire & Humberside

Easting/Northing: 429967, 434260

Latitude/Longitude: 53.803780, -1.546472


The static map below shows where the monitoring site is located.

Map showing the location of this monitoring site
» View this location on Google Maps
(new window)

» View this monitoring site on the interactive monitoring networks map

Partners

The Partners who operate networks at this monitoring sites are shown in the table below. Clicking on the Partner name will open their website in a new window.

Operator Networks
Bureau Veritas Automatic Urban Monitoring Network
Ricardo Energy & Environment Non-Automatic Hydrocarbon Network

Pollutants measured at this monitoring site

The pollutants measured at this monitoring site, grouped by network, are shown below. Use the links below to quickly jump to a specific network.

Automatic Urban Monitoring Network

Pollutant Start Date End Date Inlet Height (m) Hourly PM Measurement method
Ozone 04/01/1993 - 3.2
Nitric oxide 04/01/1993 - 3.2
Nitrogen dioxide 04/01/1993 - 3.2
Nitrogen oxides as nitrogen dioxide 04/01/1993 - 3.2
Sulphur dioxide 04/01/1993 - 3.2
Carbon monoxide 04/01/1993 - 3.2
PM10 particulate matter (Hourly measured) 04/01/1993 - 3.2 FIDAS
Non-volatile PM10 (Hourly measured) 02/12/2008 02/03/2020 Not available FDMS
Volatile PM10 (Hourly measured) 02/12/2008 02/03/2020 Not available FDMS
PM2.5 particulate matter (Hourly measured) 02/12/2008 - 3.2 FIDAS
Non-volatile PM2.5 (Hourly measured) 02/12/2008 02/03/2020 Not available FDMS
Volatile PM2.5 (Hourly measured) 02/12/2008 02/03/2020 Not available FDMS
Modelled Wind Direction 01/08/2010 - 10.0
Modelled Wind Speed 01/08/2010 - 10.0
Modelled Temperature 01/08/2010 - 2.0

Back to top

Non-Automatic Hydrocarbon Network

Pollutant Start Date End Date Inlet Height (m)
1,3-butadiene 11/06/2003 14/09/2007 Not available
benzene 26/02/2002 - 4.0

Back to top

Networks measured at this monitoring site

The listing below shows the networks that this monitoring site belongs to. You can search for sites within these networks by clicking on their name, or use the network information links to find out more about them.

Network Search Further Details Get Data
Automatic Urban and Rural Monitoring Network (AURN) Automatic Urban and Rural Monitoring Network (AURN) About network Latest pollution summary
Current Levels
Pre-Formatted Data Files
Non-Automatic Hydrocarbon Network Non-Automatic Hydrocarbon Network About network Network Information page