Site Information for Hull Freetown(UKA00450)

Hull Freetown Information

The monitoring station is located within a self-contained, air conditioning housing located on the northern edge of a car park which is situated on the northern edge of the city centre. The nearest road is approximately 3 metres from the station, this is a access road. The A165 is approximately 45 metres south of the monitoring station. Immediately to the east and west are landscaped areas of shrubs and saplings. To the north is a cul-de-sac with office buildings.

UK-AIR ID: UKA00450

EU Site ID: GB0776A

Altitude (metres): 4

Environment Type: Urban Background

PM2.5 Targets This site is used in the assessment of both the Annual Mean Concentration Target (AMCT) and Population Exposure Reduction Target (PERT) under the Environmental Target (Fine Particulate Matter) (England) Regulations 2023, subject to meeting the inclusion criteria on an annual basis. To find out more about how measurements are used to calculate progress towards the targets and which sites have met the inclusion criteria in different years, please see the PM2.5 target calculation page.

Site Location

Environment Type: Urban Background

Site Address: Hull

Government Region: Yorkshire & Humberside

Easting/Northing: 509482, 429322

Latitude/Longitude: 53.748780, -0.341222


The static map below shows where the monitoring site is located.

Map showing the location of this monitoring site
» View this location on Google Maps
(new window)

» View this monitoring site on the interactive monitoring networks map

Partners

The Partners who operate networks at this monitoring sites are shown in the table below. Clicking on the Partner name will open their website in a new window.

Operator Networks
Bureau Veritas Automatic Urban Monitoring Network
Ricardo Energy & Environment Non-Automatic Hydrocarbon Network

Pollutants measured at this monitoring site

The pollutants measured at this monitoring site, grouped by network, are shown below. Use the links below to quickly jump to a specific network.

Automatic Urban Monitoring Network

Pollutant Start Date End Date Inlet Height (m) Hourly PM Measurement method
Ozone 06/11/2002 - 3.1
Nitric oxide 06/11/2002 - 3.1
Nitrogen dioxide 06/11/2002 - 3.1
Nitrogen oxides as nitrogen dioxide 06/11/2002 - 3.1
Sulphur dioxide 06/11/2002 - 3.1
Carbon monoxide 06/11/2002 17/09/2012 4.0
PM10 particulate matter (Hourly measured) 06/11/2002 - 3.1 FIDAS
Non-volatile PM10 (Hourly measured) 20/02/2007 31/12/2014 Not available FDMS
Volatile PM10 (Hourly measured) 20/02/2007 31/12/2014 Not available FDMS
PM2.5 particulate matter (Hourly measured) 27/08/2008 - 3.1 FIDAS
Non-volatile PM2.5 (Hourly measured) 27/08/2008 12/09/2019 Not available FDMS
Volatile PM2.5 (Hourly measured) 27/08/2008 12/09/2019 Not available FDMS
Modelled Wind Direction 01/08/2010 - 10.0
Modelled Wind Speed 01/08/2010 - 10.0
Modelled Temperature 01/08/2010 - 2.0

Back to top

Non-Automatic Hydrocarbon Network

Pollutant Start Date End Date Inlet Height (m)
benzene 07/11/2002 14/11/2007 Not available

Back to top

Networks measured at this monitoring site

The listing below shows the networks that this monitoring site belongs to. You can search for sites within these networks by clicking on their name, or use the network information links to find out more about them.

Network Search Further Details Get Data
Automatic Urban and Rural Monitoring Network (AURN) Automatic Urban and Rural Monitoring Network (AURN) About network Latest pollution summary
Current Levels
Pre-Formatted Data Files
Non-Automatic Hydrocarbon Network Non-Automatic Hydrocarbon Network About network Network Information page